Home > Novell Error > Novell Error 601

Novell Error 601

For example, select LDAP and NDS, select LDAP Return Codes, then select LDAP Server Return Codes. For help with error codes that provide possible causes along with actions you can take, see SecureLogin Error Code List. All rights reserved.Server IP Addr : 192.168.100.10User Name (Full DN): admin.novell.test-treePassword: *******SDIDIAG> Additional Information Formerly known as TID# 10088628 DisclaimerThis Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties By monitoring user activities, security events, and critical systems, we provide actionable security intelligence to reduce the risk of data breach. weblink

Bookmark Email Document Printer Friendly Favorite Rating: Error -601 or ffffda7 occurs trying to login (Last modified: 23Jun2004) This document (10091591) is provided subject to the disclaimer at the end of Any trademarks referenced in this document are the property of their respective owners. Look at the trace to see why it did not match, and troubleshoot from there. Error: "(Error -601) The object name entered could not be found in the context specified. (Last modified: 09May2003) This document (10082982) is provided subject to the disclaimer at the end of

If a ndsrepair -C -Ad -A is run on the servers holding external references after the move completes for a given object The following error will be returned:Example message."ERROR -601 checking fact Novell Modular Authentication Service version 2.3 Novell BorderManager 3.8 symptom Error -601 or ffffda7 occurs trying to login Logging in using a VPN client cause The server being logged into In its first release, some people at Novell had suggested that it was so complex and powerful, there was no way they could ever release it as a red-box product. It usually means your matching rule screwed up.

Environment Novell eDirectory 8.8 for All Platforms Situation When attempting to move an object with iManager, the following error is presented:The Move Object request failed0 object(s) moved, the following object(s) could For information on error codes for LDAP, see LDAP and NDS Integration in the Novell Developer Kit (NDK). UniqueSPIException (Error -601) This error is actually pretty common. Document ID:7015658Creation Date:12-SEP-14Modified Date:22-JAN-15NovellOpen Enterprise ServerNetIQeDirectory Did this document solve your problem?

Be careful when using DN syntax attributes! Categories: Uncategorized 0 Disclaimer: As with everything else at NetIQ Cool Solutions, this content is definitely not supported by NetIQ, so Customer Support will not be able to help you if it has Watch out for data that is too long for the attribute (e.g., an attribute sized to 8 characters; adding an 11-character value is not valid). Error -605 -605 is "no such partition", and I cannot think of an Identity Manager context to generate one of those.

They are very powerful, but you need to remember that before letting the document flow to eDirectory, you should check whether there actually is a value for the attribute. Novell makes all reasonable efforts to verify this information. Click here to see the non-JavaScript version of this site. Novell SecureLogin Error Codes Overview This section contains error codes for Novell SecureLogin. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.

Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND. This error also is atomic, so you could see an add document with 20 attributes, and one of them is bad. The write will probably throw a 608 error. Learn more about Unified Communications and VoIP Management Deploy or expand Voice over IP (VoIP) Improve VoIP quality of service Maintain VoIP capacity Manage mixed unified communications (UC) Unified communications and

How can I find out WHICH Attribute is wrong. have a peek at these guys Document ID:3953579Creation Date:19-OCT-06Modified Date:16-MAR-12 Did this document solve your problem? Error -611 -611 is "illegal containment", and I have personally never triggered this one. If this is your first visit, be sure to check out the FAQ by clicking the link above.

The replica should be the same replica in which the NetWare server, which is running your Netscape Enterprise web server, is located." I don't know where else to go with this Learn more about Identity & Access Management Solution Brief: Identity Powered Security Give users quick and secure access to the resources they need Make passwords secure and simple to remember Make This would occur if you try to add an attribute to an already populated single-valued attribute. check over here Netware 6.5 (5.70) eDir 8.7.1 NDS 10510.64 ConsoleOne 1.3.6h Thanks Reply With Quote « Previous Thread | Next Thread » Bookmarks Bookmarks Twitter Facebook Google Digg del.icio.us StumbleUpon Posting Permissions You

That is left as an exercise for the administrator to extend the schema after testing that all is healthy in the tree, at an appropriate time. (I suppose that's a bit The key thing to note, before going off on a tangent, is that the UniqueSPIException Java error is really saying, eDirectory returned an error, go deal with eDirectory to resolve it. Setting a DN syntax attribute to blank is not allowed.

Log in to Reply By: geoffc Jan 2, 2008 January 2, 2008 11:40 am Reads: 4,407 Score: Unrated Print PDF Search for: Recent Commentsnsanson on NAM4, enable multiple SSL certificates for

This is often caused by typos in rules. Novell makes no explicit or implied claims to the validity of this information. Now VPN will work. Bookmark Email Document Printer Friendly Favorite Rating: ndsrepair -C -Ad -A returns "ERROR -601 checking XREF ID"This document (7015658) is provided subject to the disclaimer at the end of this document.

Learn more about IT Operations Management Understand how IT events impact business Troubleshoot and fix IT problems faster Free IT staff from routine, mundane tasks Consolidate IT tools into a master I suppose if you try to make an object in eDirectory with Object classes that are only Auxiliary or Structural classes, you would get one of these. Here are some of my personal favorites. http://themedemo.net/novell-error/novell-error-215.html Provide Feedback © Micro Focus Careers Legal close Feedback Print Full Simple Request a Call Follow Us Facebook YouTube Twitter LinkedIn Newsletter Subscription RSS NetIQ |

Consult your product manuals for complete trademark information. Environment Novell NetWare 6.5 Novell NetWare 6 Novell NetWare 5.1 SDIDIAG.EXE Version 2.1 Jun 26 2003 Situation Error: -601 when logging in with SDIDiag Error logging in: -601 Resolution Ensure that For more details see: http://www.novell.com/communities/node/2290/auxiliary-classes-and-identity-manager This is most common when you write directly to eDirectory but skip or short-circuit the engine's default behavior. (To see how the Active Directory driver handles Start thinking about why the referenced object is not there.

The new Password management snapins try to use these, but the Security Services patch is smart and does NOT blindly extend your schema when you apply it. The closest thing I've found is this article: Securing a Web Server on NetWare which has a note "Note. If not, it goes through the Creation and Placement rules to get ready to make the object in the target system. disclaimer The Origin of this information may be internal or external to Novell.

But it would take a bit of effort to trigger one of these errors. This is pretty common. With the latest releases, it is ALMOST possible to do a Click > Next style install, for some of the drivers. For the official complete set, see TID 10080995 at: http://www.novell.com/support/search.do?cmd=displayKC&docType=kc&externalId=10080995.

or more commonly in an Identity Manager trace format \ACME\ADMIN) cannot be found. Provide Feedback © Micro Focus Careers Legal close Feedback Print Full Simple Request a Call Follow Us Facebook YouTube Twitter LinkedIn Newsletter Subscription RSS Novell is Make sure that the reference to the user in the attributes "Security Equals" and "Equivalent To Me" are removed before attempting the move again. For a list of error codes that require help from Novell Technical Services, see Getting Help from Novell Technical Services.

The time now is 12:08 AM. 2016 Micro Focus Novell is now a part of Micro Focus Home Micro Focus Home Skip to Content Knowledgebase FAQ Register A fairly common example: When you apply Security services 2.05 patch to your tree, it includes new schema modifications to support some really cool new password policy options. Error -612 -612 is "cannot have multiple values". The problem is that when attempting the move, the reference to the old location is not valid anymore and the adding of the attribute fails, which causes the operation to be

The most common example is an attribute that requires Distinguished Name (DN) syntax. This attribute is part of the Aux class acmeAddOnClass in your tree. DN syntax is an example of too ‘short' a value, sort of. Resolution The error affects users that have a Security Equivalence pointing to themselves.